There are two very similar threads here so sorry
to
mix the quotes but...I have been trying this recently too - and despite the
info
copied from the adjacent thread [UKHA Wandsworth switch pics up - dim
thread -
which controller] re LD11 documentation copied here ....posted by Keith
Baker..
(who appears very frustrated on finding this info
too...)
"The
LD11
also responds to professional X-10. Combined with the memory dim feature,
the
LD11 can change the room lighting instantly or progressively."
and
"Soft (fixed) start and stop with STANDARD X10 and programmable
start
and stop rates with PROFESSIONAL X10
protocol."
and
also this posting by David Anamudu in the Comfort Technical
newsgroup
> > I
have
been playing with ActiveHome and HomeSeer, and have been able to >
get > > the ld11 units to 'soft start' to differing brightneses,
and
also to go > > immediately to different
brightnesses.
David is now not able to repeat this and I have
been
unable to get anything working using any X10 commands (Homeseer /
Homevision /
ECS / Leopard etc) - My conclusion is that any go immediate to level
function or
any 'preset the level function (whilst turned off)' is not implemented.
Also any
change of ramp speed is not possible. I think the ramped change is
unavoidable.
Unless someone knows better.... Can anyone switch an LD11 ON instantly at a
set
brightness ?
Kevin
Bummer. -
that'll
explain why I can't get it toi work then!
Oh well, I guess I'll have
o
do it like you say, - every day, I'll "reset" the dim level to 100% by
turning it on, setting the level, then turning it off again. I'll do it
as
part of my daily reset routine which runs at 05:30 every
morning.
This is for the bathroom lights, where there will be a
sensor
switch just inside the door for "normal" operation of the light, and
for
highest WAF, this should operate as normal as possible, i.e. come on at
100% brightness. However, I do intend to have some PIR activated
lighting
responses active during the night-time period to automatically turn the
lights on at only about 30% brightness whenever the bathroom door is
opened, and we have gone to bed...
ways and
means.....
Paul
G.
>From: "Kenneth Watt"
<kennwatt@xxxxxxx> >Reply-To:
ukha_d@xxxxxxx>To:
<ukha_d@xxxxxxx> >Subject: RE: [ukha_d] LD11 preset
question (with Homeseer) >Date: Wed, 20 Feb 2002 10:53:40
-0000 > >AFAIK, this is not possible as you are not sending an
X10
signal back to >the controller from a momentary
switch. > >If you want the level to change you could do what I
used to do with the >old firmware LD10's. That is at, say 10.30pm,
the
lights came on and set >to the level required, set a flag in HV so HV
could track the status of >the lights and then switched them back off
again. That way the lights, >until they reset in the morning, were
dimmed for night-time operation, >worked okay if not
ideal. > >HTH > >K. > > >
-----Original
Message----- > > From: Paul Gordon
[mailto:paul_gordon@xxxxxxx] > > Sent: 20 February 2002
10:12 > > To: ukha_d@xxxxxxx> > Subject: [ukha_d]
LD11 preset question (with Homeseer) > > > > > >
Hi
chaps, hope someone can help me, cos try as I might, I cannot
seem >to > > get > > this to work how I want
it.... > > > > I want to set a preset dim level in an
LD11
*without* turning it on, >so > > that > > the next
time it is manually operated from the momentary switch,
it >will >
> come on at that level. I need to do this from Homeseer. (no
problem >doing > > it > > via script) >
> > > I've got the LD11 device set as "Leviton dim" in Homeseer
-
If I set >it to > > "Preset dim", then dim & bright
commands sent from the Homeseer GUI >are > > not >
>
actioned. > > > > If I send it a hs.exec10 script command
with the "preset dim" >parameter, > > it > > does
precisely nothing, same goes for using the "extended" parameter. >
>
Using > > the "dim" or "bright" paramters turns the unit on at the
specified > > level... > > > > Any
thoughts?... > > > > TIA > > > > Paul
G. > > > > > >
_________________________________________________________________ >
>