[Date Prev][Date
Next][Thread Prev][Thread Next][Date
Index][Thread Index]
RE: help! AW10 going pop
- To: <ukha_d@xxxxxxx>
- Subject: RE: help! AW10 going pop
- From: "Roger" <roger@xxxxxxx>
- Date: Tue, 26 Feb 2002 16:14:16 -0000
- Delivered-to: mailing list ukha_d@xxxxxxx
- Mailing-list: list ukha_d@xxxxxxx; contact
ukha_d-owner@xxxxxxx
- Reply-to: ukha_d@xxxxxxx
RTFM (Read The F****** Manual ----- or could be Ring The Fire-Brigade
Mate!)
On LetsAutomate the ratings re given as:
10A Resistive (AC assumed)
3A Motor
Incandescent 2000W
As an immersion heater is slightly inductive (anyone ever measure one?) the
current rating will be a bit less than 10A
Roger Shingler
-----Original Message-----
From: kinchyuk [mailto:kinchyuk@xxxxxxx]
Sent: 26 February 2002 15:52
To: ukha_d@xxxxxxx
Subject: [ukha_d] help! AW10 going pop
Just wired up an AW10 to an 3kW immersion heater, when I tap the
switch there's a loud pop, a blue flash, and not a lot happens - the
load remains switched on whatever. The red light on the front doesn't
light at all.
Taken everything apart, wiring is fine. Any suggestions? Is 3kW a bit
much for an AW10?
Alex
For more information: http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe: ukha_d-subscribe@xxxxxxx
Unsubscribe: ukha_d-unsubscribe@xxxxxxx
List owner: ukha_d-owner@xxxxxxx
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
Home |
Main Index |
Thread Index
|