Kevin

Yes, I noticed from the data stream that the 'old' Southern Electric
one doesn't have the software version stuff either and does run at
2400 rather than 9600.=20=20

However, last night I saw that they were again selling the newer
displays only for =A315 on ebay so I 'had' to buy one of them - just
waiting for delivery.  So rather than taking you up on the kind offer
to change your app, I hope the new one will be directly compatible.=20=20

I suggest I do a direct test with the new one as soon as it arrives
and we take it from there.  Is that ok?

Regards

Richard

--- In xap_automation@xxxxxxx, Kevin Hawkins
<yahoogroupskh@...> wrote:
>
> Thanks Kevin...
>=20
>     What I'd missed is that the baud rate is different too - so I
will=20
> need to change the application for you Richard.  I have a feeling it
has=20
> a fixed serial port number at the moment - what would suit you Richard
?
>=20
>     K
>=20
> turner228 wrote:
> >
> > With apologies for replying to myself :)
> > but some additional informstion
> >
> > In the Southern Electric's xml the src section is as follows
> >
> > <src>
> > <name>CC02</name>
> > <id>01356</id>
> > <type>1</type>
> > </src>
> >
> > In what I assume is the newer directly supplied display the src
> > section is
> >
> > <src>
> > <name>CC02</name>
> > <id>03017</id>
> > <type>1</type>
> > <sver>1.06</sver>
> > </src>
> >
> > Ignoring the id, which I believe to be the ID of the clamp
> > transmitter, the difference is the sver, ie the software version,
> > which does not exist in the lower capability display
> >
> > Kevin T
> > www.netcomp.biz
> >
> > --- In xap_automation@xxxxxxx=20
> > <mailto:xap_automation%40yahoogroups.com>,
"turner228" <kevin@> wrote:
> > >
> > > I have two of the CurrentCost LCD displays which I have been
> > playing
> > > with.
> > >
> > > The original one was "Southern Electric"'s special
offer, and the
> > > port is set for 2400 baud and only supplies current data.
> > >
> > > The second one from CurrentCost's ebay shop runs at 9600baud
and
> > has
> > > a full set of data
> > >
> > > HTH
> > >
> > > Kevin T
> > > (the other kevin)
> > > www.netcomp.biz
> > >
> > > --- In xap_automation@xxxxxxx=20
> > <mailto:xap_automation%40yahoogroups.com>,
"rb_ziggy"
> > > <richard.boreham@> wrote:
> > > >
> > > > Kevin
> > > >
> > > > Thanks for that - I'll remember on the mail front;-)
> > > >
> > > > I'm quite taken with the device so if there is a prob
with the
> > > > software version, I'd be tempted to track down a
version with the
> > > > historic data for logging purposes. (Leaving the other
in the
> > > kitchen
> > > > to persuade others to turn off things!)
> > > >
> > > > Regards
> > > >
> > > > Richard
> > > >
> > > > --- In xap_automation@xxxxxxx=20
> > <mailto:xap_automation%40yahoogroups.com>,
Kevin Hawkins
> > > > <yahoogroupskh@> wrote:
> > > > >
> > > > > Hi Richard,
> > > > >
> > > > > I'm afraid I don't read every post on UKHA and I
missed
> > > that one
> > > > > as it's under a topic for a product I don't have.
(Wattson)
> > A
> > > > direct
> > > > > email is likley the best way to contact me ;-)
> > > > >
> > > > > I'll dig out the code and just check what
dependencies it
> > > has -
> > > > > probably only the latest Intranet OCX which I'm
sure you
> > have.
> > > I'm
> > > > not
> > > > > sure how (if) it will cope with the historic data
not being
> > > provided in
> > > > > your version of the Current Cost but try it and
see.
> > > > >
> > > > > Kevin
> > > > >
> > > > > rb_ziggy wrote:
> > > > > >
> > > > > > Kevin
> > > > > >
> > > > > > I posted on UKHA where you had offered up
your partially
> > > developed xAP
> > > > > > interface for the CurrentCost meter.
> > > > > >
> > > > > > I'd be very interested in acquiring a copy if
possible and
> > > giving it a
> > > > > > try.
> > > > > >
> > > > > > Many thanks
> > > > > >
> > > > > > Richard
> > > > > >
> > > > > >
> > > > >
> > > >
> > >
> >
> >
>



------------------------------------


xAP_Automation Main Index | xAP_Automation Thread Index | xAP_Automation Home | Archives Home