Doh.

Thanks for the help; I need to decide if I think the problem is bad
enough (only _minor_ disturbance, and only when it is switched on) to
warrant sending it in for replacement, and the lottery of what I might
get back in return!

Steve

-----Original Message-----
From: Nick Austin [mailto:nick1@xxxxxxx]
Sent: 02 October 2003 19:45
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] Re: Help - Is my TiVo faulty?

*** WARNING ***

This mail has originated outside your organization,
either from an external partner or the Global Internet.
Keep this in mind if you answer this message.

Steve,

Oh dear.  AFAIK the Aux Scart does not have any output pins,
so snipping wires is unlikely to help.  Also if the fault is
not present using the Aux button this too suggests that the
Scart cabling is OK and there are no earth loops.

Seems as though it's a TiVo internal problem.

Nick.

At 01:50 PM 2003-10-02 +0100, Crick, Steve (UK) wrote:

>I like easy questions; the answers are No and RGB + PAL and RGB +
>PAL(SCART control ON).
>
>Thanks - Steve
>
>
>-----Original Message-----
>From: Nick Austin [mailto:nick1@xxxxxxx]
>Sent: 02 October 2003 09:07
>To: ukha_d@xxxxxxx
>Subject: RE: [ukha_d] Re: Help - Is my TiVo faulty?
>
>*** WARNING ***
>
>This mail has originated outside your organization,
>either from an external partner or the Global Internet.
>      Keep this in mind if you answer this message.
>
>Steve,
>
>It does sound like a classic case of cross-talk within the cable.  If
>the left-right movement freezes when TiVo is paused that suggests it's
>the cable connecting the Sky box to the Tivo.
>
>Two questions:
>
>Do you still see the problem when using the TiVo AUX button?
>
>What are the TiVo settings for "Aux Source" and "Video
Output to TV"
>under the "SCART Settings" menu?
>
>Nick.
>
>At 08:44 AM 2003-10-02 +0100, Crick, Steve (UK) wrote:
>
> >Thanks for the advice, I am not clued up on electrics. My Sky box
and
> >TiVo don't have any earth connections, and the 'fault' freezes
then I
> >pause the TiVo.
> >
> >Would an Isolator be appropriate?
> >
> >Thanks - Steve
> >
> >-----Original Message-----
> >From: ianh1000 [mailto:ianh1000@xxxxxxx]
> >Sent: 01 October 2003 20:15
> >To: ukha_d@xxxxxxx
> >Subject: [ukha_d] Re: Help - Is my TiVo faulty?
> >
> >*** WARNING ***
> >
> >This mail has originated outside your organization,
> >either from an external partner or the Global Internet.
> >      Keep this in mind if you answer this message.
> >
> >Hi
> >
> >Not sure if this is similar to a ground loop issue i had. I have a
> >Tivo and also an HP MP3 Jukebox. I had a complete nightmare with
the
> >video display for the Jukebox as it had a similar display issue to
> >that you describe. This seemed to be caused by the Earth on my
cable
> >TV causing a ground loop, I have managed to fix this recently with
an
> >inline Isolator from Telesignal ( very nice people) A filter would
> >not stop the groundloop if that is your problem.
> >
> >Regards
> >Ian
> >
> >
> >--- In ukha_d@xxxxxxx, "stevecrick2000"
<steve.crick@b...>
> >wrote:
> > > Hi all,
> > >
> > > The warrenty is almost up and I notice a fault. Can anybody
tell
me
> > > is this a known issue with a work around, or is it
broken....
> > >
> > > With the new TV in place, I have started to use RGB for the
TiVo
> > > connection. On dark areas of the picture, I have noticed
what can
> > > only be described as 'smoke' blowing from left to right,
with a
> > > sweep time of around a second.
> > >
> > > Not major, but noticable (even by SWMBO), and now we see it,
it is
> > > annoying.
> > >
> > > After tireless faultfinding I have tracked it down, and I
think
the
> > > TiVo is faulty. It only occurs on RGB when the TiVo is on
(rather
> > > than standby). Nothing is noticable when Sky is on direct
view. So
> >I
> > > think the TiVo sees a return echo from the output (but it
still
> >does
> > > it with no TV SCART connected).
> > >
> > > The best way to spot it is to put Sky onto a music channel,
as the
> > > solid blue background shows a band of 'pixels' sweeping from
left
> >to
> > > right. The pixels freeze if I pause the TiVo (so not the
TV).
> > >
> > > I have done everything possible; I use topdraw SCARTS; I
have
moved
> > > TiVo and Sky; used FreeView instead; re-routed SCARTS and
audio
> > > leads (cross-talk?); changed the mains feed (and added
filters);
> > > Nothing stops it.
> > >
> > > My warrenty is up in a few days, and I woundered if anybody
sees
> > > anything like this on their TiVos, or has heard of a fix?
> > >
> > > Thanks in advance.
> > > Steve
> >
> >
> >
> >
> >UKHA 2004: 15th and 16th May 2004
> >
> >http://www.automatedhome.co.uk
> >Post message: ukha_d@xxxxxxx
> >Subscribe:  ukha_d-subscribe@xxxxxxx
> >Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> >List owner:  ukha_d-owner@xxxxxxx
> >
> >Your use of Yahoo! Groups is subject to
> >http://docs.yahoo.com/info/terms/
> >
> >
> >
> >
>
>********************************************************************
> >This email and any attachments are confidential to the intended
> >recipient and may also be privileged. If you are not the intended
> >recipient please delete it from your system and notify the sender.
> >You should not copy it or use it for any purpose nor disclose or
> >distribute its contents to any other person.
>
>********************************************************************
> >
> >
> >UKHA 2004: 15th and 16th May 2004
> >
> >http://www.automatedhome.co.uk
> >Post message: ukha_d@xxxxxxx
> >Subscribe:  ukha_d-subscribe@xxxxxxx
> >Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
> >List owner:  ukha_d-owner@xxxxxxx
> >
> >Your use of Yahoo! Groups is subject to
>http://docs.yahoo.com/info/terms/
>
>
>
>UKHA 2004: 15th and 16th May 2004
>
>http://www.automatedhome.co.uk
>Post message: ukha_d@xxxxxxx
>Subscribe:  ukha_d-subscribe@xxxxxxx
>Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
>List owner:  ukha_d-owner@xxxxxxx
>
>Your use of Yahoo! Groups is subject to
>http://docs.yahoo.com/info/terms/
>
>
>
>
>********************************************************************
>This email and any attachments are confidential to the intended
>recipient and may also be privileged. If you are not the intended
>recipient please delete it from your system and notify the sender.
>You should not copy it or use it for any purpose nor disclose or
>distribute its contents to any other person.
>********************************************************************
>
>
>UKHA 2004: 15th and 16th May 2004
>
>http://www.automatedhome.co.uk
>Post message: ukha_d@xxxxxxx
>Subscribe:  ukha_d-subscribe@xxxxxxx
>Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
>List owner:  ukha_d-owner@xxxxxxx
>
>Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/



UKHA 2004: 15th and 16th May 2004

http://www.automatedhome.co.uk
Post message: ukha_d@xxxxxxx
Subscribe:  ukha_d-subscribe@xxxxxxx
Unsubscribe:  ukha_d-unsubscribe@xxxxxxx
List owner:  ukha_d-owner@xxxxxxx

Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/




********************************************************************
This email and any attachments are confidential to the intended
recipient and may also be privileged. If you are not the intended
recipient please delete it from your system and notify the sender.
You should not copy it or use it for any purpose nor disclose or
distribute its contents to any other person.
********************************************************************


Home | Main Index | Thread Index

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.