As part of the questions are related to my application (IRM).. I'll try
to
answer you:
> Now the serial interface board actually has to decode the IR (HV
used to
do that
> for you) and generate an ASCII command string - is that right ?
> Actually I guess what would make it clearer to me is the serial to
PC
> protocol if you are willing to release it.
The signal decoding is now a PC task, inside the IRM application
> Finally - what are the limitations of FirM that you are aware
of. I am
> a newbie to IR and a bit confused but have thoughts like:
>1) Different remotes use different frequencies - any problem ?
For the moment the application is compatible only with the remotes using
a
carrier between 30-40KHz. The old ITT ones, using small pulses and no
carrier ar not supported. Anyway, I think that the majority of the
actual
remotes use a carrier.
> 2) Some keys send multi command sequences etc - any problem ?
What do you mean by multi command sequence? Multiple commands transmitted
in
a sequence? If yes, then I'm not aware of such remotes...Anyway, the
application is able then to consider the multicommand sequence as a
single
command, so is not a problem... Please give me more details about this
type
of remotes and I will take care of...